Modular 40ton 50HP Industrial Water Cooled Water Cooling Chiller
Product Description:
Anyda series of water cooled industrial chillers are capable of controlling precisely the mold temperature in plastic molding process as so to shorten molding cycle and speed product formalization. The principle of heat exchange is adopted for cooling. They can achieve rapid cooling, stable temperature controlling, and will be little effected by the surrounding factors. Therefore they are necessary good equipments in modern industry.
1. Cooling temperature range 5-35 degrees
2.High-capacity tube-in-shell evaporator with very good heat exchange performance especially under high ambient temperature condition.
3. Tube-in-shell condensers with excellent heat transfer and rapid cooling.
4. Stainless steel warm-keeping water tank.
5.R22 refrigerant to be used for efficient cooling.
6. R407 environment-friendly refrigerant is optional to use.
7. Overload protection for compressor, pump.
8. Independent temperature controller, anti-freeze protection.
9. Phase sequence protection for control circuit, refrigeration loop controlled by high and low pressure switch.
10. Warm-keeping design for all piping to avoid partial convection.
11. Suitable for machine cooling in industries of plastics, electroplating, foodstuff, electronic products, bleaching and dyeing, ultrasonics.
Applied Machinery: Cooling system of oil temperature, ultrasonic, high frequency machinery,injection molding machinery, blow molding machinery.
Item | Specification / Supplier | ||
Cooling capacity | Model | AYD-50W | |
kw/h | 165 | ||
Power input | kw | 43.23 | |
Power supply | 380V-3N-50HZ | ||
Temp Outlet (ºC) | 7 | ||
refrigerant control | Expansion valve | ||
Refrigeration circle | four | ||
refrigerant | R22 | ||
Dimension(mm)L×W×H | 2200*1500*1900 | ||
Compressor | Style | Scroll | |
Quantity(set) | 4 | ||
Compressor Power(kw) | 37.4 | ||
Condenser | Style | Shell and Tube / 1set | |
Pipe size(DN) | 80 | ||
Cooling tower flow(m3/h) | 33.5 | ||
Evaporator | Style | Shell and Tube / 1set | |
Cold water flow(m3/h) | 27.5 | ||
Pipe size(DN) | 80 | ||
Water Tank(L) | 500 | ||
Pump Power(kw/h) | 3.75 | ||
Protector Device | 1,Phase protector 2,Fan overload protector 3,High/low voltage protector 4,overheat protector 5,Anti-freeze protector |
||
Unit Weight(kg) | 1500 | ||
Operating Weight(kg) | 1800 | ||
Main Parts | |||
Compressor | Panasonic | ||
Electronic | LS / Carlo | ||
Electromagnetically valve | Emerson | ||
Expansion Valve | Emerson | ||
Electrical control | Punp |
FAQ:
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.Types of chiller system?
Air Cooled Chiller and Water Cooled Chiller.Water cooled chiller needs a separated cooling tower and has a higher efficiency,but less easier than air cooled.
4.Cooling capacity unit conversion?
1 kcal/h = 1.163W,1 W = 0.8598 kcal/h;
1 Btu/h = 0.2931W,1 W = 3.412 Btu/h;
1 USRT = 3.517 kW,1 kW = 0.28434 USRT;
1 kcal/h = 3.968 Btu/h,1 Btu/h = 0.252 kcal/h;
1 USRT = 3024 kcal/h,10000 kcal/h = 3.3069 USRT;
5.This chiller could do heat recovery?
Yes,please kindly send us the temp and water volume per hour.
6.Chiller maintenance?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant
Why Choose Us?
1.Reply your inquiry within 12 working hrs.
2.Strong R&D team,more than 15 years of manufacturing chiller experience. OEM&ODM is welcomed.
3.Direct factory,offer customer competitive price with high quality chiller.
4.Strict quality control system,professional QC team.